Our Low Profile Air Handling
Units have been specially designed in house to cater for the need
that exists between fan coils units and air handling units. These
compact yet powerful units can be combined with our heating and cooling
coils, sound attenuators and mixing sections to provide a complete
system for any environment.
Mixing box
The mixing box will be provided with a top fresh air intake connection
and rear connection for re-circulated air. Air mixture will be controlled
by a single skin aluminium blade damper, suitable for either motorised
or manual operation.
Opposed blade dampers can be provided as an alternative when requested.
Filter and Fan section
This is a combined section housing both the filter and fans. The
fans are forward curved double inlet type, which are single phase
and are capable of controlling airflow by means of voltage regulation.
The unit is fully insulated with flame retardant material.
Manometers are available as optional extras to detect filter efficiency.
Fans and Motors
Each unit will be fitted with one two or three direct driven double
inlet fans mounted on a 16 gauge box tray section, ribbed to provide
adequate stiffness and to prevent drumming or distortion.
Filters
Located in the air intake section, the fitters are of the disposable
type and can be removed from either top or bottom of the unit as
specified at time of order.
Heating Coil
The heating coil will be manufactured from copper tubes expanded
into the collars of aluminium fins by a mechanical process that
ensures maximum heat transfer under all operating conditions. The
tubes are brazed into copper return bends and headers, terminating
with BSP male connections. Manual air vents are provided as standard.
Cooling coil
The cooling coil will be manufactured from copper tubes expanded
into the collars formed in aluminium fins by a mechanical process
that ensures maximum heat transfer under all operating conditions.
A drip tray will be supplied as standard.
The cooling coil can be manufactured from copper tubes and fins
and electro tinned after manufacture.
Sound attenuators
The sound attenuators will comprise of tissue faced air splitters
to provide low noise levels during operations. These are housed
in a duct section with hanging brackets as standard.
Discharge plenum
The discharge plenum can be provided with either a rectangular
spigot for connecting to ductwork or circular spigots suitable for
connecting to flexible ducting.
Electric heaters
These can be supplied in a variety of outputs, stages and voltages
to suit most requirements.
Bag filters
The bag type filters are an alternative and addition to the filters
already in the fan/ filter section, they provide a more effective
form of filtration than conventional filters and are preferable
in areas where cleanliness is a criteria.
|